Showing posts with label ICX. Show all posts
Showing posts with label ICX. Show all posts

Thursday, November 10, 2016

Finding EPS Power Supply Status on Brocade ICX Switches

It took me a while to figure this out, so here it is:

To find out how your chassis is doing on your Brocade ICX type the show chassis command.

The stack unit 1 chassis info:

Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 (NA - AC - Regular) present, status ok

Fan ok, speed (auto): [[1]]<->2

Fan speed switching temperature thresholds:
        1 -> 2 @ 69 deg-C
        1 <- 2 @ 64 deg-C

Sensor B Temperature Readings:
        Current temperature : 29.5 deg-C
Sensor A Temperature Readings:
        Current temperature : 38.0 deg-C
        Warning level.......: 66.0 deg-C
        Shutdown level......: 76.0 deg-C
Boot Prom MAC : cc4e.24xx.xxxx
Management MAC: cc4e.24xx.xxxx


If you only care about the power supply status type:
sh chassis | incl Power

Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 (NA - AC - Regular) present, status ok
Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 (NA - AC - Regular) present, status ok
Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 (NA - AC - Regular) present, status ok

This is the output for my switches which are 3 ICX 6450s stacked. 6450s only have a single built-in power supply, so "Power supply 2" in each case is the EPS. In my setup I have one EPS powering two switches and another one powering the last switch. There's no way to know what "Power supply 2" is with a command, as far as I know.